MahaRERA Application

General Information

Other Than Individual

Organization

VENKATESH ASSOCIATES
Partnership
NA
Do you have any Past Experience ?
Yes

Address Details

S.NO.50/2
PLATINUM CLASSIC
PUNE NAGAR ROAD
KHARADI
CHANDAN NAGAR
MAHARASHTRA
Pune
Pune
Haveli
KHARADI
411014

Organization Contact Details

08888064444

Past Experience Details

Sr.No.
Project Name
Type of Project
Others
Land Area(In Sq mtrs)
Address
CTS Number
Number of Buildings/Plot
Number of Apartments
Original Proposed Date of Completion
Actual Date of Completion
1OXY PRIMOOthersRESIDENTIAL & COMMERCIAL8600GAT NO 559 1 WAGHOLI TAL HAVELI PUNE559 1 PLOT NO 1 2 3 422312015-06-302016-09-01

Member Information

Member Name Designation Photo
KIRAN VASANT PAWAR Partner View Photo
SUNIL DILIP DEOKAR Partner View Photo
RAHUL KONDIBA SATAV Authorized Signatory View Photo
SANDIP KONDIBA SATAV Partner View Photo
DEVIDAS DNYANOBA KADAM Partner View Photo

Project

OXY EVOLVE
On-Going Project
31/10/2017
31/12/2019
No
Residential
Yes
1140
Amenity space
Adjourning Road
Gat No 1140 Part
12 meter Road
MAHARASHTRA
Pune
Pune
Haveli
WAGHOLI
412207
8000
3
3
0
753.86

FSI Details

0
9657.77
9657.77

Bank Details

STATE BANK OF INDIA
SBIN0001110

Promoter(Land Owner/ Investor) Details

Project Name Promoter Name Promoter(Land Owner/ Investor) Type Type of Agreement/ Arrangement Office Number Other Details
OXY EVOLVE MANIBHAI DESAI CO OP HOUSING SOCIETY Societies Area Share NA Address : MANIBHAI DESAI CO OP SOCIETY ,GAT NO 1140 ,DOMKHEL ROAD ,WAGHOLI ,NEAR RAISONI COLLAGE ,Division :Pune ,District :Pune ,Taluka :Haveli ,Village :WAGHOLI ,412207 ,27

Project Details

Name Proposed Booked WorkDone(In %)
Number of Garages ( In Numbers) 0 0 0
Covered Parking ( In Numbers) 127 34 70

Development Work

Common areas And Facilities, Amenities Available Percent Details
Internal Roads & Footpaths : YES 100 WIP
Water Conservation, Rain water Harvesting : YES 85 WIP
Energy management : YES 85 WIP
Fire Protection And Fire Safety Requirements : YES 70 WIP
Electrical Meter Room, Sub-Station, Receiving Station : YES 70 WIP
Aggregate area of recreational Open Space : YES 70 WIP
Open Parking : NO 0 NA
Water Supply : YES 80 WIP
Sewerage (Chamber, Lines, Septic Tank , STP) : YES 90 WIP
Storm Water Drains : YES 80 WIP
Landscaping & Tree Planting : YES 90 WIP
Street Lighting : YES 90 WIP
Community Buildings : YES 100 COMPLETE
Treatment And Disposal Of Sewage And Sullage Water : YES 100 COMPLETE
Solid Waste Management And Disposal : YES 100 COMPLETE

Building Details

Sr.No. Project Name Name Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Slab of Super Structure Number of Stilts Number of Open Parking Number of Closed Parking
1 OXY EVOLVE A 31/12/2019 1 1 0 13 1 0 34
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 3 BHK 62.25 1 1
2 1 BHK 36.43 1 1
3 1 BHK 40.33 1 1
4 1 bhk 28.32 8 8
5 2 BHK 46.43 10 2
6 1 BHK 32.70 12 12
7 2 BHK 52.19 11 9
8 2 BHK 48.17 11 5
9 2 bhk 53.85 10 8
10 1 bhk 33.74 9 9
11 2 BHK 49.62 9 7
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 100
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 100
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 100
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

100
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 100
11 Overall Percentage of Completion of the work done For the entire Building /Wing 90
Sr.No. Project Name Name Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Slab of Super Structure Number of Stilts Number of Open Parking Number of Closed Parking
2 OXY EVOLVE B 1 1 0 12 1 0 59
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 2 BHK 50.44 6 0
2 1 BHK 35.96 6 0
3 1 BHK 32.38 4 0
4 2 BHK 49.77 4 0
5 1 BHK 33.97 4 0
6 2 BHK 47.09 6 0
7 2 BHK 45.40 4 0
8 1 BHK 33.65 2 0
9 1 BHK 35.24 2 0
10 2 BHK 51.76 4 0
11 2 BHK 51.51 1 0
12 1 BHK 31.89 2 0
13 2 BHK 50.78 2 0
14 1 BHK 33.50 1 0
15 2 BHK 47.37 1 0
16 1 BHK 28.63 1 0
17 1 BHK 37.65 1 0
18 1 BHK 34.13 6 0
19 3 BHK 62.91 1 0
20 1 BHK 30.22 1 0
21 1 BHK 30.09 1 0
22 2 BHK 46.45 8 0
23 1 BHK 32.26 4 0
24 1 BHK 33.78 4 0
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 70
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 30
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 80
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

85
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 30
11 Overall Percentage of Completion of the work done For the entire Building /Wing 69.5
Sr.No. Project Name Name Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Slab of Super Structure Number of Stilts Number of Open Parking Number of Closed Parking
3 OXY EVOLVE C 31/12/2019 1 1 0 12 1 0 34
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 1 BHK 40.33 1 1
2 1 BHK 28.32 8 4
3 2 BHK 53.85 10 6
4 2 BHK 46.43 8 1
5 3 BHK 62.25 1 1
6 1 BHK 33.74 9 9
7 1 BHK 36.43 1 1
8 1 BHK 32.70 10 10
9 2 BHK 52.19 9 9
10 2 BHK 48.17 9 4
11 2 BHK 49.62 9 5
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 100
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 100
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 100
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

100
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 100
11 Overall Percentage of Completion of the work done For the entire Building /Wing 90

Project Professional Information

Professional Name MahaRERA Certificate No. Professional Type
MR R K RANDHAVE NA Structural Engineer
MR ATIT ADMULWAR NA Architect
MR NITIN GOVIND HOLE NA

Litigations Details

Uploaded Documents

Document Name Uploaded Document
Copy of Layout Approval (in case of layout)
Building Plan Approval (IOD)
Building Plan Approval (IOD)
Building Plan Approval (IOD)
Building Plan Approval (IOD)
Building Plan Approval (IOD)
Building Plan Approval (IOD)
Declaration in FORM B
Copy of the legal title report
Details of encumbrances
Proforma of the allotment letter and agreement for sale
Commencement Certificates
Other
Status of Formation of Legal Entity (Society/Co Op etc.)
Status of Conveyance
Certificates of Architect (Form 4)