MahaRERA Application

General Information

Other Than Individual

Organization

VARAD DEVELOPERS
Partnership
NA
Do you have any Past Experience ?
Yes

Address Details

CS NO.249 A/1/27/A FLAT NO.103
VARAD RESIDENCY
NAGALA PARK
NAGALA PARK
VIVEKANAND COLLEGE
MAHARASHTRA
Pune
Kolhapur
Karvir
Kolhapur (M Corp.)
416003

Organization Contact Details

02312657349
varaddevelopers.in

Past Experience Details

Sr.No.
Project Name
Type of Project
Others
Land Area(In Sq mtrs)
Address
CTS Number
Number of Buildings/Plot
Number of Apartments
Original Proposed Date of Completion
Actual Date of Completion
1VARAD RESIDENCYResidentialNA930.20249249/A1/27A1162012-02-032012-08-01
2Himmat Bhahadur EnclaveResidentialNA200023231392013-12-172014-04-05

Member Information

Member Name Designation Photo
PREETI SANJAY CHAVAN Authorized Signatory View Photo
VIBHAVARI CHANDRAKANT CHAVAN Authorized Signatory View Photo
SANJAY CHANDRAKANT CHAVAN Authorized Signatory View Photo

Project

CLYDE HOMES
On-Going Project
10/10/2019
01/07/2020
No
Residential
No
SURVEY NUMBER 209A/1 , 1K/1, 1K/2
SURVEY NUMBER 209A
SURVEY NUMBER 209A
SURVEY NUMBER 209A
12 M WIDE ROAD
MAHARASHTRA
Pune
Kolhapur
Karvir
Kolhapur (M Corp.)
KARANDE MALA
TARABAI PARK
416003
2800
2
2
0
200

FSI Details

429.06
4216.32
4645.38

Bank Details

BANK OF BARODA
BARB0SHAHUP

Project Details

Name Proposed Booked WorkDone(In %)
Number of Garages ( In Numbers) 0 0 0
Covered Parking ( In Numbers) 44 26 70

Development Work

Common areas And Facilities, Amenities Available Percent Details
Internal Roads & Footpaths : NO 0 NA
Water Conservation, Rain water Harvesting : YES 0 Bore well recharge
Energy management : YES 0 Solar for hot water for Master Bed only
Fire Protection And Fire Safety Requirements : YES 0 As per Municipal Approval
Electrical Meter Room, Sub-Station, Receiving Station : YES 0 M.S.C.B. Norms
Aggregate area of recreational Open Space : YES 10 As per Municipal
Open Parking : YES 60 Car Parking
Water Supply : YES 0 MUNICIPAL/BORE WELL
Sewerage (Chamber, Lines, Septic Tank , STP) : YES 0 150MM dia. pipe will be connected to municipal
Storm Water Drains : YES 0 Connected to Municipal Gutter
Landscaping & Tree Planting : YES 0 As per Drawings
Street Lighting : NO 0 NA
Community Buildings : NO 0 NA
Treatment And Disposal Of Sewage And Sullage Water : YES 0 For Landscape
Solid Waste Management And Disposal : NO 0 NA

Building Details

Sr.No. Project Name Name Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Slab of Super Structure Number of Stilts Number of Open Parking Number of Closed Parking
1 CLYDE HOMES CLYDE HOMES A WING 1 1 0 7 0 0 0
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 3BHK 169.93 1 0
2 4BHK 187.45 1 0
3 4BHK 185.00 1 0
4 4BHK 185.07 1 0
5 4BHK 184.29 1 0
6 4BHK 190.39 1 1
7 4BHK 183.66 1 1
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 0
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 70
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 70
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 70
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

70
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 0
11 Overall Percentage of Completion of the work done For the entire Building /Wing 58
Sr.No. Project Name Name Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Slab of Super Structure Number of Stilts Number of Open Parking Number of Closed Parking
2 CLYDE HOMES CLYDE HOMES B WING 2 1 0 10 0 12 0
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 2BHK 70.80 4 0
2 3BHK 97.15 5 3
3 2BHK 67.35 8 5
4 2BHK 63.90 6 1
5 2BHK 65.06 1 0
6 3BHK 95.50 5 4
7 3BHK 84.25 6 0
8 3BHK 87.75 2 0
9 2BHK 69.84 1 1
10 2BHK 73.35 1 0
11 2BHK 74.60 1 1
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 0
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 50
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 50
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 50
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

50
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 0
11 Overall Percentage of Completion of the work done For the entire Building /Wing 50

Project Professional Information

Professional Name MahaRERA Certificate No. Professional Type
Prashant Kapadi NA Architect
Pranav Kulkarni NA Structural Engineer
Chetan J Patil NA Structural Engineer

Litigations Details

Uploaded Documents

Document Name Uploaded Document
Commencement Certificates
Commencement Certificates
Copy of Layout Approval (in case of layout)
Copy of Layout Approval (in case of layout)
Building Plan Approval (IOD)
Building Plan Approval (IOD)
Copy of the legal title report
Proforma of the allotment letter and agreement for sale
Declaration in FORM B
Details of encumbrances
Status of Conveyance
Certificates of Architect (Form 4)
Other
Status of Formation of Legal Entity (Society/Co Op etc.)