MahaRERA Application

General Information

Other Than Individual

Organization

Sancheti Properties
Partnership
NA
Do you have any Past Experience ?
Yes

Address Details

401
Renata Chambers
2145
Sadashiv Peth
N.C. Phadke Chowk
MAHARASHTRA
Pune
Pune
Pune City
Pune (M Corp.)
411030

Organization Contact Details

02024332276
www.sanchetibuilders.com

Past Experience Details

Sr.No.
Project Name
Type of Project
Others
Land Area(In Sq mtrs)
Address
CTS Number
Number of Buildings/Plot
Number of Apartments
Original Proposed Date of Completion
Actual Date of Completion
1Belcastel Phase IResidentialNA8233.89Keshavnagar Mundhwa Pune-4110363171962015-05-032015-09-03
2Eves GardenResidentialNA16241Keshavnagar Mundhwa Pune- 4110363474592017-03-162017-06-16

Member Information

Member Name Designation Photo
Pukhraj Bansilal Sancheti Partner View Photo
Kishor Bansilal Sancheti Partner View Photo
Sancheti Associates Pvt Ltd Authorized Signatory View Photo

Project

Belcastel Phase II
On-Going Project
31/03/2018
31/12/2018
No
Residential
No
31
By Club House
By STP and OWP
By 4 Bunglows of Lonkar
By First Phase
MAHARASHTRA
Pune
Pune
Pune City
Keshavnagar-Mundwa
Keshavnagar
Mundhwa
411036
8530.66
2
2
0
1972

FSI Details

8530.66
482.92
9013.58

Bank Details

Janata Sahakari Bank Ltd,
JSBP0000098

Project Details

Name Proposed Booked WorkDone(In %)
Number of Garages ( In Numbers) 0 0 0
Covered Parking ( In Numbers) 130 130 100

Development Work

Common areas And Facilities, Amenities Available Percent Details
Internal Roads & Footpaths : YES 100 Completed
Water Conservation, Rain water Harvesting : YES 100 Completed
Energy management : NO 0 NA
Fire Protection And Fire Safety Requirements : YES 100 As Per Sanction Plan
Electrical Meter Room, Sub-Station, Receiving Station : YES 100 Sub Station Completed
Aggregate area of recreational Open Space : YES 100 Some Work Balance
Open Parking : YES 100 As per Plan
Water Supply : YES 100 Tanker Supply
Sewerage (Chamber, Lines, Septic Tank , STP) : YES 100 As Per Requirement
Storm Water Drains : NO 0 NA
Landscaping & Tree Planting : YES 100 As Per Plan
Street Lighting : YES 100 As Per Requirement
Community Buildings : YES 100 Completed
Treatment And Disposal Of Sewage And Sullage Water : YES 100 STP Completed
Solid Waste Management And Disposal : NO 0 NA

Building Details

Sr.No. Project Name Name (Also mention identification of building/wing/other as per approved plan) Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Sanctioned Floors Number of Stilts Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler) Number of Closed Parking
1 Belcastel Phase II C1 31/12/2018 0 1 1 11 1 24 68
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 2BHK 75.15 5 5
2 2BHK 75.00 12 12
3 2BHK 72.23 4 4
4 2BHK 76.60 1 1
5 2BHK 75.29 1 1
6 2BHK 72.24 1 1
7 1BHK 37 1 1
8 2BHK 71.85 5 5
9 2BHK 75.28 5 5
10 2BHK 75.43 6 6
11 2BHK 76.51 5 5
12 3BHK 105.13 1 1
13 2BHK 77.08 5 5
14 2BHK 76.59 11 11
15 2BHK 74.81 10 10
16 2BHK 71.98 5 5
17 2BHK 75.66 5 5
18 2BHK 72.10 5 5
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 100
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 100
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 100
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 100
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

100
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 100
11 Overall Percentage of Completion of the work done For the entire Building /Wing 100
Sr.No. Project Name Name (Also mention identification of building/wing/other as per approved plan) Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Sanctioned Floors Number of Stilts Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler) Number of Closed Parking
2 Belcastel Phase II C2 31/12/2018 0 1 1 11 1 23 62
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 2BHK 71.85 5 5
2 2BHK 72.24 1 1
3 2BHK 76.60 1 1
4 2BHK 74.81 10 10
5 2BHK 75.29 1 1
6 2BHK 75.15 5 5
7 2BHK 76.59 11 11
8 2BHK 75.66 5 5
9 2BHK 75.00 12 12
10 2BHK 71.98 5 5
11 2BHK 77.08 5 5
12 2BHK 76.51 5 4
13 2BHK 75.43 6 5
14 2BHK 75.28 5 5
15 2BHK 72.10 5 4
16 2BHK 72.23 5 5
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 100
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 100
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 100
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 100
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

100
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 100
11 Overall Percentage of Completion of the work done For the entire Building /Wing 100

Project Professional Information

Professional Name MahaRERA Certificate No. Professional Type
K. R. Pal (RCC Work) NA Contractor
Gangubai Y. Pawar ( B.B.M & Plaster Work) NA Contractor
Miss Sunita Ajinath Bankar (painting Work) NA Contractor
Nitin Shinde (Electrical Work) NA Contractor
Narayan Meghawat ( Waterproofing Work) NA Contractor
Buddhisagar Chavan (Tile Work) NA Contractor
Dinkar Dhone (Plumbing Work) NA Contractor
Jaychand Chawan (Fabrication) NA Contractor
S. R. Jadhav (Painting Work) NA Contractor
Rahim Khan ( B.B.M & Plaster Work) NA Contractor
Sudhanshu Chanda (Plumbing Work) NA Contractor
Digambar Dinde (P.O.P. Work) NA Contractor
Deshmukh (Tile Work) NA Contractor
Shirish Dasnurkar & Associates NA Architect
G.A. Bhilare NA Engineer
SATINDERPALSINGH JOGINDERPALSINGH ARORA A52100004752 Real Estate Agent

Litigations Details

Uploaded Documents

Document Name Uploaded Document
1 Copy of the legal title report
1 Details of encumbrances
1 b Details of encumbrances concerned to Legal
1 Copy of Layout Approval (in case of layout)
1 Building Plan Approval (IOD)
2 Building Plan Approval (IOD)
3 Building Plan Approval (IOD)
4 Building Plan Approval (IOD)
5 Building Plan Approval (IOD)
6 Building Plan Approval (IOD)
7 Building Plan Approval (IOD)
8 Building Plan Approval (IOD)
9 Building Plan Approval (IOD)
10 Building Plan Approval (IOD)
11 Building Plan Approval (IOD)
12 Building Plan Approval (IOD)
13 Building Plan Approval (IOD)
14 Building Plan Approval (IOD)
15 Building Plan Approval (IOD)
16 Building Plan Approval (IOD)
17 Building Plan Approval (IOD)
1 Commencement Certificates / NA Order for plotted development
2 Commencement Certificates / NA Order for plotted development
3 Commencement Certificates / NA Order for plotted development
1 Declaration about Commencement Certificate
1 Declaration in FORM B
1 Certificates of Architect (Form 1)(Mandatory for only ongoing project)
1 Certificates of Engineer (Form 2)(Mandatory for only ongoing project)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2019-20)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2020-21)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2021-22)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2022-23)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2023-24)
1 Disclosure of sold/ booked inventory
1 CERSAI details
1 Disclosure of Interest in Other Real Estate Organizations
1 Certificates of CA (Form 5)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2018-19)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2019-20)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2020-21)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2021-22)
1 Proforma of Agreement for sale
1 Annual Audit Report of Statutory CA (Form 5) (FY 2022-23)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2023-24)
1 Proforma of Allotment letter
2 Proforma of Allotment letter
1 Occupancy Certificate/ Completion Certificate/ Architect's certificate of completion for plotted development
2 Occupancy Certificate/ Completion Certificate/ Architect's certificate of completion for plotted development
1 Certificates of Architect (Form 4)
2 Certificates of Architect (Form 4)
1 Status of Formation of Legal Entity (Society/Co Op etc.)
1 Status of Conveyance
2 Status of Conveyance
3 Status of Conveyance
4 Status of Conveyance
5 Status of Conveyance
6 Status of Conveyance
1 Other
1 Other – Finance
1 Other – Technical
1 Foreclosure of the Project
1 Deviation Report with respect to Allotment letter
1 Deviation Report with respect to model copy of Agreement