Sr.No. |
Project Name
|
Name (Also mention identification of building/wing/other as per approved plan)
|
Proposed Date of Completion
|
Number of Basement's
|
Number of Plinth
|
Number of Podium's
|
Number of Sanctioned Floors
|
Number of Stilts
|
Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler)
|
Number of Closed Parking
|
1 |
SILVERLAND RESIDENCY PHASE III
|
A MHADA-COMM
|
31/12/2021
|
0
|
1
|
0
|
8
|
0 |
12 |
0 |
|
|
Sr.No.
|
Apartment Type
|
Carpet Area (in Sqmts)
|
Number of Apartment
|
Number of Booked Apartment
|
1 |
SHOP AND MAZENINE FL |
41.66 |
1 |
0 |
2 |
SHOP AND MAZENINE FL |
43.62 |
1 |
0 |
3 |
SHOP AND MAZENINE FL |
43.64 |
1 |
0 |
4 |
SHOP AND MAZENINE FL |
64.49 |
1 |
0 |
5 |
1 BHK |
35.54 |
12 |
5 |
6 |
1 BHK |
41.05 |
11 |
4 |
|
|
|
|
|
Sr.No.
|
Tasks / Activity
|
Percentage of Work
|
1
|
Excavation
|
100
|
2
|
X number of Basement(s) and Plinth
|
100
|
3
|
X number of Podiums
|
100
|
4
|
Stilt Floor
|
100
|
5
|
X number of Slabs of Super
Structure
|
100
|
6
|
Internal walls, Internal Plaster,
Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises
|
100
|
7
|
Sanitary Fittings within the
Flat/Premises,Electrical Fittings within the Flat/Premises
|
100
|
8
|
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.
|
100
|
9
|
The external plumbing and external plaster,
elevation, completion of terraces with waterproofing of the Building/Wing
|
100
|
10
|
Installation of lifts, water pumps, Fire
Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common
Areas, electro, mechanical equipment, Compliance to conditions of environment
/CRZ NOC,
Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to
Building/Wing, Compound Wall and all other requirements as may be required to
Obtain Occupation /Completion Certificate
|
100
|
11 |
Overall Percentage of Completion of the
work done For the entire Building /Wing
|
100
|
|
Sr.No. |
Project Name
|
Name (Also mention identification of building/wing/other as per approved plan)
|
Proposed Date of Completion
|
Number of Basement's
|
Number of Plinth
|
Number of Podium's
|
Number of Sanctioned Floors
|
Number of Stilts
|
Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler)
|
Number of Closed Parking
|
2 |
SILVERLAND RESIDENCY PHASE III
|
B
|
31/12/2021
|
0
|
1
|
1
|
12
|
0 |
02 |
64 |
|
|
Sr.No.
|
Apartment Type
|
Carpet Area (in Sqmts)
|
Number of Apartment
|
Number of Booked Apartment
|
1 |
1BHK |
37.41 |
5 |
3 |
2 |
2BHK |
43.46 |
5 |
3 |
3 |
2BHK |
46.99 |
5 |
2 |
4 |
2BHK |
48.13 |
2 |
0 |
5 |
1 BHK |
38.49 |
2 |
1 |
6 |
2 BHK |
44.14 |
8 |
2 |
7 |
2BHK |
44.05 |
3 |
1 |
8 |
1BHK |
33.50 |
4 |
3 |
9 |
2BHK |
44.37 |
8 |
8 |
10 |
2BHK |
43.16 |
4 |
3 |
11 |
2BHK |
44.16 |
10 |
4 |
12 |
2BHK |
44.40 |
10 |
9 |
|
|
|
|
|
Sr.No.
|
Tasks / Activity
|
Percentage of Work
|
1
|
Excavation
|
100
|
2
|
X number of Basement(s) and Plinth
|
0
|
3
|
X number of Podiums
|
100
|
4
|
Stilt Floor
|
100
|
5
|
X number of Slabs of Super
Structure
|
100
|
6
|
Internal walls, Internal Plaster,
Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises
|
100
|
7
|
Sanitary Fittings within the
Flat/Premises,Electrical Fittings within the Flat/Premises
|
100
|
8
|
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.
|
100
|
9
|
The external plumbing and external plaster,
elevation, completion of terraces with waterproofing of the Building/Wing
|
100
|
10
|
Installation of lifts, water pumps, Fire
Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common
Areas, electro, mechanical equipment, Compliance to conditions of environment
/CRZ NOC,
Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to
Building/Wing, Compound Wall and all other requirements as may be required to
Obtain Occupation /Completion Certificate
|
100
|
11 |
Overall Percentage of Completion of the
work done For the entire Building /Wing
|
90
|
|
Sr.No. |
Project Name
|
Name (Also mention identification of building/wing/other as per approved plan)
|
Proposed Date of Completion
|
Number of Basement's
|
Number of Plinth
|
Number of Podium's
|
Number of Sanctioned Floors
|
Number of Stilts
|
Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler)
|
Number of Closed Parking
|
3 |
SILVERLAND RESIDENCY PHASE III
|
C
|
31/12/2021
|
0
|
1
|
1
|
12
|
0 |
02 |
66 |
|
|
Sr.No.
|
Apartment Type
|
Carpet Area (in Sqmts)
|
Number of Apartment
|
Number of Booked Apartment
|
1 |
2 BHK |
48.13 |
1 |
0 |
2 |
1 BHK |
38.49 |
2 |
0 |
3 |
2 BHK |
44.14 |
9 |
0 |
4 |
2 BHK |
44.05 |
3 |
0 |
5 |
2 BHK |
43.46 |
5 |
1 |
6 |
2 BHK |
46.99 |
5 |
1 |
7 |
1 BHK |
37.41 |
5 |
2 |
8 |
1 BHK |
33.50 |
4 |
3 |
9 |
2 BHK |
44.37 |
9 |
6 |
10 |
2 BHK |
43.16 |
5 |
1 |
11 |
2 BHK |
44.16 |
10 |
2 |
12 |
2 BHK |
44.40 |
10 |
7 |
|
|
|
|
|
Sr.No.
|
Tasks / Activity
|
Percentage of Work
|
1
|
Excavation
|
100
|
2
|
X number of Basement(s) and Plinth
|
100
|
3
|
X number of Podiums
|
100
|
4
|
Stilt Floor
|
100
|
5
|
X number of Slabs of Super
Structure
|
100
|
6
|
Internal walls, Internal Plaster,
Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises
|
100
|
7
|
Sanitary Fittings within the
Flat/Premises,Electrical Fittings within the Flat/Premises
|
100
|
8
|
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.
|
100
|
9
|
The external plumbing and external plaster,
elevation, completion of terraces with waterproofing of the Building/Wing
|
100
|
10
|
Installation of lifts, water pumps, Fire
Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common
Areas, electro, mechanical equipment, Compliance to conditions of environment
/CRZ NOC,
Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to
Building/Wing, Compound Wall and all other requirements as may be required to
Obtain Occupation /Completion Certificate
|
100
|
11 |
Overall Percentage of Completion of the
work done For the entire Building /Wing
|
100
|
|
Sr.No. |
Project Name
|
Name (Also mention identification of building/wing/other as per approved plan)
|
Proposed Date of Completion
|
Number of Basement's
|
Number of Plinth
|
Number of Podium's
|
Number of Sanctioned Floors
|
Number of Stilts
|
Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler)
|
Number of Closed Parking
|
4 |
SILVERLAND RESIDENCY PHASE III
|
D
|
31/12/2021
|
0
|
1
|
1
|
12
|
0 |
03 |
73 |
|
|
Sr.No.
|
Apartment Type
|
Carpet Area (in Sqmts)
|
Number of Apartment
|
Number of Booked Apartment
|
1 |
2 BHK |
48.58 |
1 |
1 |
2 |
2 BHK |
44.14 |
8 |
3 |
3 |
2 BHK |
37.38 |
3 |
3 |
4 |
2 BHK |
43.16 |
4 |
1 |
5 |
2 BHK |
47.66 |
3 |
1 |
6 |
2 BHK |
43.57 |
4 |
4 |
7 |
2 BHK |
50.92 |
4 |
3 |
8 |
2 BHK |
43.85 |
5 |
4 |
9 |
1 BHK |
37.51 |
3 |
3 |
10 |
1 BHK |
37.41 |
10 |
4 |
11 |
1 BHK |
33.50 |
1 |
1 |
12 |
2 BHK |
44.40 |
10 |
2 |
13 |
2 BHK |
43.18 |
5 |
0 |
14 |
2 BHK |
48.88 |
5 |
2 |
15 |
2 BHK |
50.95 |
5 |
2 |
16 |
1 BHK |
40.93 |
1 |
0 |
17 |
1 BHK |
33.30 |
1 |
0 |
18 |
2 BHK |
48.13 |
1 |
0 |
19 |
2 BHK |
40.21 |
1 |
0 |
20 |
2 BHK |
51.44 |
1 |
0 |
|
|
|
|
|
Sr.No.
|
Tasks / Activity
|
Percentage of Work
|
1
|
Excavation
|
100
|
2
|
X number of Basement(s) and Plinth
|
0
|
3
|
X number of Podiums
|
100
|
4
|
Stilt Floor
|
100
|
5
|
X number of Slabs of Super
Structure
|
100
|
6
|
Internal walls, Internal Plaster,
Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises
|
100
|
7
|
Sanitary Fittings within the
Flat/Premises,Electrical Fittings within the Flat/Premises
|
100
|
8
|
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.
|
100
|
9
|
The external plumbing and external plaster,
elevation, completion of terraces with waterproofing of the Building/Wing
|
100
|
10
|
Installation of lifts, water pumps, Fire
Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common
Areas, electro, mechanical equipment, Compliance to conditions of environment
/CRZ NOC,
Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to
Building/Wing, Compound Wall and all other requirements as may be required to
Obtain Occupation /Completion Certificate
|
100
|
11 |
Overall Percentage of Completion of the
work done For the entire Building /Wing
|
90
|
|