MahaRERA Application

General Information

Other Than Individual

Organization

Niraj Kumar Associates Pvt Ltd
Company
NA
Do you have any Past Experience ?
Yes

Address Details

129/2
Mont Vert Marc
Pashan Sus Rd
pashan
Above Union bank
MAHARASHTRA
Pune
Pune
Haveli
Pashan
411021

Organization Contact Details

02025872633

Past Experience Details

Sr.No.
Project Name
Type of Project
Others
Land Area(In Sq mtrs)
Address
CTS Number
Number of Buildings/Plot
Number of Apartments
Original Proposed Date of Completion
Actual Date of Completion
1AvionResidentialNA60001401A Pashan-Sus Rd Pashan140 1A2932017-12-312018-07-31

Member Information

Member Name Designation Photo
Jayant Vallabhdas Kaneria Managing Director View Photo

Project

Mont Vert Avion
On-Going Project
31/12/2017
31/12/2017
31/07/2018
No
Others
No
140/1A
140 2 CTS 1183 p
140 1A CTS 1183 p
140 1A CTS 1183 p
36m wide road
MAHARASHTRA
Pune
Pune
Haveli
Pashan
Pashan-Sus Rd
Pashan
411021
6000
2
2
0
553.18

FSI Details

9085
238.16
9323.16

Bank Details

HDFC Bank
HDFC0000060

Project Details

Name Proposed Booked WorkDone(In %)
Number of Garages ( In Numbers) 0 0 0
Covered Parking ( In Numbers) 95 86 85

Development Work

Common areas And Facilities, Amenities Available Percent Details
Internal Roads & Footpaths : YES 100 Internal Driways yet to be done
Water Conservation, Rain water Harvesting : YES 100 Recharge pits and STP
Energy management : YES 100 Solar water heater and LED common lights
Fire Protection And Fire Safety Requirements : YES 100 will be completed before completion
Electrical Meter Room, Sub-Station, Receiving Station : YES 100 Transformer room
Swimming Pool : YES 100 Excavation to start soon
Aggregate area of recreational Open Space : YES 100 peripheral development
Open Parking : NO 0 NA
Water Supply : YES 100 Will apply for PMC connection after completion
Sewerage (Chamber, Lines, Septic Tank , STP) : YES 100 STP yet to be installed
Storm Water Drains : YES 100 will be installed before peripheral development
Landscaping & Tree Planting : YES 100 will be done after peripheral work
Street Lighting : YES 0 No streets but internal driway lights
Community Buildings : YES 100 One community building
Treatment And Disposal Of Sewage And Sullage Water : YES 100 will be operational before occupancy
Solid Waste Management And Disposal : YES 100 will be operational before occupancy

Building Details

Sr.No. Project Name Name (Also mention identification of building/wing/other as per approved plan) Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Sanctioned Floors Number of Stilts Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler) Number of Closed Parking
1 Mont Vert Avion Mont Vert Avion Residential 31/12/2017 3 1 0 20 1 0 95
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 3 RHK 95.12 19 18
2 4 RHK Duplex 166.29 2 2
3 2 RHK 64.66 34 28
4 2.5 RHK 81 19 17
5 3 RHK 104.1 19 17
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 100
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 100
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 100
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

100
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 100
11 Overall Percentage of Completion of the work done For the entire Building /Wing 90
Sr.No. Project Name Name (Also mention identification of building/wing/other as per approved plan) Proposed Date of Completion Number of Basement's Number of Plinth Number of Podium's Number of Sanctioned Floors Number of Stilts Total no. of open Parking as per Sanctioned Plan (4-wheeler+2-Wheeler) Number of Closed Parking
2 Mont Vert Avion Mont Vert Avion Commercial 2 1 0 3 1 0 12
Sr.No. Apartment Type Carpet Area (in Sqmts) Number of Apartment Number of Booked Apartment
1 Office 203 60.57 1 1
2 Office 101 92.05 1 1
3 Office 102 92.03 1 1
4 Office 201 60.57 1 1
5 Office 202 60.24 1 1
Sr.No. Tasks / Activity Percentage of Work
1 Excavation 100
2 X number of Basement(s) and Plinth 100
3 X number of Podiums 0
4 Stilt Floor 100
5 X number of Slabs of Super Structure 100
6 Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises 100
7 Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises 100
8 Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. 100
9

The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing

100
10 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate 100
11 Overall Percentage of Completion of the work done For the entire Building /Wing 90

Project Professional Information

Professional Name MahaRERA Certificate No. Professional Type
Arch. Avinash Nawathe NA Architect
Hansal Parikh NA Engineer
Ronisun Knowledge Application Center A52100005788 Real Estate Agent

Litigations Details

Uploaded Documents

Document Name Uploaded Document
1 Copy of the legal title report
1 Details of encumbrances
1 b Details of encumbrances concerned to Legal
1 Copy of Layout Approval (in case of layout)
1 Building Plan Approval (IOD)
2 Building Plan Approval (IOD)
1 Commencement Certificates / NA Order for plotted development
1 Declaration about Commencement Certificate
1 Declaration in FORM B
1 Certificates of Architect (Form 1)(Mandatory for only ongoing project)
2 Certificates of Architect (Form 1)(Mandatory for only ongoing project)
1 Certificates of Engineer (Form 2)(Mandatory for only ongoing project)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2019-20)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2020-21)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2021-22)
1 Engineers Certificate on Quality Assurance (Form 2A FY 2022-23)
1 Disclosure of sold/ booked inventory
1 CERSAI details
1 Disclosure of Interest in Other Real Estate Organizations
1 Certificates of CA (Form 5)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2018-19)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2019-20)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2020-21)
1 Annual Audit Report of Statutory CA (Form 5) (FY 2021-22)
1 Proforma of Agreement for sale
1 Annual Audit Report of Statutory CA (Form 5) (FY 2022-23)
1 Proforma of Allotment letter
2 Proforma of Allotment letter
3 Proforma of Allotment letter
1 Occupancy Certificate/ Completion Certificate/ Architect's certificate of completion for plotted development
1 Certificates of Architect (Form 4)
2 Certificates of Architect (Form 4)
1 Status of Formation of Legal Entity
2 Status of Formation of Legal Entity
1 Status of Conveyance
1 Other
2 Other
3 Other
4 Other
1 Other – Finance
1 Other – Technical
1 Foreclosure of the Project
1 Deviation Report with respect to Allotment letter
1 Deviation Report with respect to model copy of Agreement